Data Enabler Pro

Installation Instructions

PDF-000251-01 R07

19 November 209

Must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.
Before installing this product, please visit the product page at www.colorkinetics.com for the latest version of the installation instructions. Due to continuous improvements and innovations, installation instructions may change without notice.

  1. Confirm all components received

  1. Verify the electrical plan and all necessary surge protection requirements.

Important Surge Protection Requirement: www.colorkinetics.com/KB/surge-protection
  1. Ensure latest firmware is running and update as necessary.

See Firmware Updates for complete instructions.
  1. Installation planning

Use Configuration Calculator to help identify and locate all luminaires, Data Enabler Pro devices, and controllers and to calculate the number of luminaires each circuit can support based on model, line voltage, circuit load, and cable lengths.
  1. Make sure power is OFF

  2. Permanent Installation

  1. Remove cover and appropriate seal plugs.

  1. Tighten cable connectors to manufacturers specification and torque seal plug to approximately 19 in-lb (2.2 Nm).

    For wet or damp locations, seal all points of entry to prevent water infiltration. Use RTV silicone and weatherproof junction boxes.
  2. Connect data – DMX

  3. Connect data – Ethernet

  1. Attach power cable

  1. Connect luminaire cable

Connect luminaire cable - iColor Accent Powercore

  1. Secure cover

Torque to approximately 16 in-lb (1.8 Nm)
  1. Turn the power ON.

Verify power is off before installing or de-installing.
Do not attempt to install or use the Data Enabler Pro until you have read and understand the installation instructions and safety labels.
Do not use the Data Enabler Pro for any voltage for which it is not rated. Do not exceed the specified voltage and current input rating. Only for use with specified Color Kinetics Lighting products.
It is the end user’s responsibility to comply with these installation instructions and to determine appropriate conductor size to permanently connect the incoming facility, and to provide means for disconnecting the system.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.
Warning - This is a Class A product. In a domestic environment this product may cause radio frequency interference in which case the user may be required to take adequate measures.
This Class A digital apparatus complies with Canadian ICES-003.
Warning - This is a class A product. In a domestic environment this product may cause radio frequency interference in which case the user may be required to take adequate measures.

© 2019 Signify Holding. All rights reserved. Specifications are subject to change without notice. No representation or warranty as to the accuracy or completeness of the information included herein is given and any liability for any action in reliance thereon is disclaimed.